Lara B. Hedrick

Evaluation of a New Sediment Sampling Device

A two-part sediment sampler (stationary base and removable trap) was designed for a long-term study of stream sedimentation associated with highway construction. Before the long-term study, a laboratory study in an experimental flume examined efficacies of our sampler and two other sediment samplers: a modified core sampler and Whitlock-Vibert boxes. Based on the flume experiment, the efficacy of our sediment sampler was consistent with that of core and Whitlock-Vibert samplers. The advantage of our two-part sediment sampler design is that it allows for repeated removal of sediment samples...